;/*++ BUILD Version: 0001 // Increment this if a change has global effects ; ;Copyright (c) 1992, 1993 Digi International ; ;Module Name: ; ; ntepclog.h ; ;Abstract: ; ; Constant definitions for the I/O error code log values. ; ;Author: ; ; Rik Logan ; ;Revision History: ; ;--*/ ; ;#ifndef _NTEPCLOG_ ;#define _NTEPCLOG_ ; ;// ;// Status values are 32 bit values layed out as follows: ;// ;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 ;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 ;// +---+-+-------------------------+-------------------------------+ ;// |Sev|C| Facility | Code | ;// +---+-+-------------------------+-------------------------------+ ;// ;// where ;// ;// Sev - is the severity code ;// ;// 00 - Success ;// 01 - Informational ;// 10 - Warning ;// 11 - Error ;// ;// C - is the Customer code flag ;// ;// Facility - is the facility code ;// ;// Code - is the facility's status code ;// ; MessageIdTypedef=NTSTATUS SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS Informational=0x1:STATUS_SEVERITY_INFORMATIONAL Warning=0x2:STATUS_SEVERITY_WARNING Error=0x3:STATUS_SEVERITY_ERROR ) FacilityNames=(System=0x0 RpcRuntime=0x2:FACILITY_RPC_RUNTIME RpcStubs=0x3:FACILITY_RPC_STUBS Io=0x4:FACILITY_IO_ERROR_CODE Serial=0x6:FACILITY_SERIAL_ERROR_CODE ) MessageId=0x1001 Facility=Serial Severity=Error SymbolicName=SERIAL_NO_CONTROLLER_RESET_WAIT Language=English Unable to reset %2. Wait confirmation failed. Compare I/O address settings with configuration. Otherwise, check for I/O address conflicts with another device in the system. . MessageId=0x1002 Facility=Serial Severity=Error SymbolicName=SERIAL_CONTROLLER_MEMORY_TEST_FAILED Language=English Unable to properly access %2's memory. Compare Memory address settings with configuration. Otherwise, check for memory address conflicts with another device in the system. . MessageId=0x1003 Facility=Serial Severity=Error SymbolicName=SERIAL_BIOS_DOWNLOAD_FAILED Language=English Downloading BIOS image to %2 failed. . MessageId=0x1004 Facility=Serial Severity=Error SymbolicName=SERIAL_FEPOS_COPY_FAILED Language=English Failure copying FEPOS program to %2. . MessageId=0x1005 Facility=Serial Severity=Error SymbolicName=SERIAL_FEPOS_INIT_FAILURE Language=English FEPOS failed to initialize properly on %2. . MessageId=0x1006 Facility=Serial Severity=Error SymbolicName=SERIAL_INSUFFICIENT_RESOURCES Language=English Not enough memory was available to allocate internal storage needed for the device %1. . MessageId=0x1007 Facility=Serial Severity=Error SymbolicName=SERIAL_NO_EPC_MODULES Language=English No EPC PORTS modules were found connected to %2. Shutdown system, turn off your computer and connect an EPC PORTS module. . MessageId=0x1008 Facility=Serial Severity=Error SymbolicName=SERIAL_REGISTRY_VALUE_NOT_FOUND Language=English The registry entry %2 could not be found. . MessageId=0x1009 Facility=Serial Severity=Error SymbolicName=SERIAL_FILE_NOT_FOUND Language=English Unable to find file %2. . MessageId=0x100A Facility=Serial Severity=Error SymbolicName=STATUS_DEVICE_NOT_INITIALIZED Language=English Controller %2 could not be initialized. . ;#endif /* _NTEPCLOG_ */