;/*++ BUILD Version: 0001 // Increment this if a change has global effects
;
;Copyright (c) 1992, 1993 Digi International
;
;Module Name:
;
; ntxemlog.h
;
;Abstract:
;
; Constant definitions for the I/O error code log values.
;
;Author:
;
; Rik Logan
;
;Revision History:
;
;--*/
;
;#ifndef _NTXEMLOG_
;#define _NTXEMLOG_
;
;//
;// Status values are 32 bit values layed out as follows:
;//
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
;// +---+-+-------------------------+-------------------------------+
;// |Sev|C| Facility | Code |
;// +---+-+-------------------------+-------------------------------+
;//
;// where
;//
;// Sev - is the severity code
;//
;// 00 - Success
;// 01 - Informational
;// 10 - Warning
;// 11 - Error
;//
;// C - is the Customer code flag
;//
;// Facility - is the facility code
;//
;// Code - is the facility's status code
;//
;
MessageIdTypedef=NTSTATUS
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS
Informational=0x1:STATUS_SEVERITY_INFORMATIONAL
Warning=0x2:STATUS_SEVERITY_WARNING
Error=0x3:STATUS_SEVERITY_ERROR
)
FacilityNames=(System=0x0
RpcRuntime=0x2:FACILITY_RPC_RUNTIME
RpcStubs=0x3:FACILITY_RPC_STUBS
Io=0x4:FACILITY_IO_ERROR_CODE
Serial=0x6:FACILITY_SERIAL_ERROR_CODE
)
MessageId=0x1001 Facility=Serial Severity=Error SymbolicName=SERIAL_NO_CONTROLLER_RESET_WAIT
Language=English
Unable to reset %2. Wait confirmation failed. Compare I/O address settings with configuration.
Otherwise, check for I/O address conflicts with another device in the system.
.
MessageId=0x1002 Facility=Serial Severity=Error SymbolicName=SERIAL_CONTROLLER_MEMORY_TEST_FAILED
Language=English
Unable to properly access %2's memory. Compare Memory address settings with configuration.
Otherwise, check for memory address conflicts with another device in the system.
.
MessageId=0x1003 Facility=Serial Severity=Error SymbolicName=SERIAL_BIOS_DOWNLOAD_FAILED
Language=English
Downloading BIOS image to %2 failed.
.
MessageId=0x1004 Facility=Serial Severity=Error SymbolicName=SERIAL_FEPOS_COPY_FAILED
Language=English
Failure copying FEPOS program to %2.
.
MessageId=0x1005 Facility=Serial Severity=Error SymbolicName=SERIAL_FEPOS_INIT_FAILURE
Language=English
FEPOS failed to initialize properly on %2.
.
MessageId=0x1006 Facility=Serial Severity=Error SymbolicName=SERIAL_INSUFFICIENT_RESOURCES
Language=English
Not enough memory was available to allocate internal storage needed for the device %1.
.
MessageId=0x1007 Facility=Serial Severity=Error SymbolicName=SERIAL_NO_XEM_MODULES
Language=English
No Xem PORTS modules were found connected to %2. Shutdown system, turn off your computer and connect an Xem PORTS module.
.
MessageId=0x1008 Facility=Serial Severity=Error SymbolicName=SERIAL_REGISTRY_VALUE_NOT_FOUND
Language=English
The registry entry %2 could not be found.
.
MessageId=0x1009 Facility=Serial Severity=Error SymbolicName=SERIAL_FILE_NOT_FOUND
Language=English
Unable to find file %2.
.
MessageId=0x100A Facility=Serial Severity=Error SymbolicName=STATUS_DEVICE_NOT_INITIALIZED
Language=English
Controller %2 could not be initialized.
.
;#endif /* _NTXEMLOG_ */