118 lines
3.4 KiB
MonkeyC
118 lines
3.4 KiB
MonkeyC
;/*++ BUILD Version: 0001 // Increment this if a change has global effects
|
||
;
|
||
;Copyright (c) 1992, 1993 Digi International
|
||
;
|
||
;Module Name:
|
||
;
|
||
; ntxemlog.h
|
||
;
|
||
;Abstract:
|
||
;
|
||
; Constant definitions for the I/O error code log values.
|
||
;
|
||
;Author:
|
||
;
|
||
; Rik Logan
|
||
;
|
||
;Revision History:
|
||
;
|
||
;--*/
|
||
;
|
||
;#ifndef _NTXEMLOG_
|
||
;#define _NTXEMLOG_
|
||
;
|
||
;//
|
||
;// Status values are 32 bit values layed out as follows:
|
||
;//
|
||
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
|
||
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
|
||
;// +---+-+-------------------------+-------------------------------+
|
||
;// |Sev|C| Facility | Code |
|
||
;// +---+-+-------------------------+-------------------------------+
|
||
;//
|
||
;// where
|
||
;//
|
||
;// Sev - is the severity code
|
||
;//
|
||
;// 00 - Success
|
||
;// 01 - Informational
|
||
;// 10 - Warning
|
||
;// 11 - Error
|
||
;//
|
||
;// C - is the Customer code flag
|
||
;//
|
||
;// Facility - is the facility code
|
||
;//
|
||
;// Code - is the facility's status code
|
||
;//
|
||
;
|
||
MessageIdTypedef=NTSTATUS
|
||
|
||
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS
|
||
Informational=0x1:STATUS_SEVERITY_INFORMATIONAL
|
||
Warning=0x2:STATUS_SEVERITY_WARNING
|
||
Error=0x3:STATUS_SEVERITY_ERROR
|
||
)
|
||
|
||
FacilityNames=(System=0x0
|
||
RpcRuntime=0x2:FACILITY_RPC_RUNTIME
|
||
RpcStubs=0x3:FACILITY_RPC_STUBS
|
||
Io=0x4:FACILITY_IO_ERROR_CODE
|
||
Serial=0x6:FACILITY_SERIAL_ERROR_CODE
|
||
)
|
||
|
||
|
||
MessageId=0x1001 Facility=Serial Severity=Error SymbolicName=SERIAL_NO_CONTROLLER_RESET_WAIT
|
||
Language=English
|
||
Unable to reset %2. Wait confirmation failed. Compare I/O address settings with configuration.
|
||
Otherwise, check for I/O address conflicts with another device in the system.
|
||
.
|
||
|
||
MessageId=0x1002 Facility=Serial Severity=Error SymbolicName=SERIAL_CONTROLLER_MEMORY_TEST_FAILED
|
||
Language=English
|
||
Unable to properly access %2's memory. Compare Memory address settings with configuration.
|
||
Otherwise, check for memory address conflicts with another device in the system.
|
||
.
|
||
|
||
MessageId=0x1003 Facility=Serial Severity=Error SymbolicName=SERIAL_BIOS_DOWNLOAD_FAILED
|
||
Language=English
|
||
Downloading BIOS image to %2 failed.
|
||
.
|
||
|
||
MessageId=0x1004 Facility=Serial Severity=Error SymbolicName=SERIAL_FEPOS_COPY_FAILED
|
||
Language=English
|
||
Failure copying FEPOS program to %2.
|
||
.
|
||
|
||
MessageId=0x1005 Facility=Serial Severity=Error SymbolicName=SERIAL_FEPOS_INIT_FAILURE
|
||
Language=English
|
||
FEPOS failed to initialize properly on %2.
|
||
.
|
||
|
||
MessageId=0x1006 Facility=Serial Severity=Error SymbolicName=SERIAL_INSUFFICIENT_RESOURCES
|
||
Language=English
|
||
Not enough memory was available to allocate internal storage needed for the device %1.
|
||
.
|
||
|
||
MessageId=0x1007 Facility=Serial Severity=Error SymbolicName=SERIAL_NO_XEM_MODULES
|
||
Language=English
|
||
No Xem PORTS modules were found connected to %2. Shutdown system, turn off your computer and connect an Xem PORTS module.
|
||
.
|
||
|
||
MessageId=0x1008 Facility=Serial Severity=Error SymbolicName=SERIAL_REGISTRY_VALUE_NOT_FOUND
|
||
Language=English
|
||
The registry entry %2 could not be found.
|
||
.
|
||
|
||
MessageId=0x1009 Facility=Serial Severity=Error SymbolicName=SERIAL_FILE_NOT_FOUND
|
||
Language=English
|
||
Unable to find file %2.
|
||
.
|
||
|
||
MessageId=0x100A Facility=Serial Severity=Error SymbolicName=STATUS_DEVICE_NOT_INITIALIZED
|
||
Language=English
|
||
Controller %2 could not be initialized.
|
||
.
|
||
|
||
;#endif /* _NTXEMLOG_ */
|
||
|