WindowsXP-SP1/admin/hmonitor/hmagent/pmde.cpp
2020-09-30 16:53:49 +02:00

609 lines
15 KiB
C++

//***************************************************************************
//
// PMDE.CPP
//
// Module: HEALTHMON SERVER AGENT
//
// Purpose: CPolledMethodDataCollector class to do WMI instance collection.
//
// Copyright (c)1999 Microsoft Corporation, All Rights Reserved
//
//***************************************************************************
#include "pmde.h"
//////////////////////////////////////////////////////////////////////
//////////////////////////////////////////////////////////////////////
// Construction/Destruction
//////////////////////////////////////////////////////////////////////
CPolledMethodDataCollector::CPolledMethodDataCollector()
{
MY_OUTPUT(L"ENTER ***** CPolledMethodDataCollector...", 4);
//
// XXX
//
#ifdef SAVE
m_pHMEventSink = NULL;
#endif
m_szObjectPath = NULL;
m_szMethodName = NULL;
m_deType = HM_PMDE;
m_lNumInstancesCollected = 0;
m_pCallResult = NULL;
MY_OUTPUT(L"EXIT ***** CPolledMethodDataCollector...", 4);
}
CPolledMethodDataCollector::~CPolledMethodDataCollector()
{
int iSize;
int i;
PARSTRUCT *pparameter;
MY_OUTPUT(L"ENTER ***** ~CPolledMethodDataCollector...", 4);
if (m_szObjectPath)
delete [] m_szObjectPath;
if (m_szMethodName)
delete [] m_szMethodName;
iSize = m_parameterList.size();
for (i=0; i<iSize ;i++)
{
MY_ASSERT(i<m_parameterList.size());
pparameter = &m_parameterList[i];
if (pparameter->szName)
{
delete [] pparameter->szName;
}
if (pparameter->szValue)
{
delete [] pparameter->szValue;
}
}
EnumDone();
MY_OUTPUT(L"EXIT ***** ~CPolledMethodDataCollector...", 4);
}
//
// Load a single DataCollector, and everything under it.
//
HRESULT CPolledMethodDataCollector::LoadInstanceFromMOF(IWbemClassObject* pObj, CDataGroup *pParentDG, LPTSTR pszParentObjPath, BOOL bModifyPass/*FALSE*/)
{
BOOL bRetValue = TRUE;
VARIANT v;
VARIANT vValue;
IUnknown* vUnknown;
IWbemClassObject* pCO;
long iLBound, iUBound;
long lType;
PARSTRUCT par;
int iSize;
long i;
PARSTRUCT *pparameter;
HRESULT hRetRes = S_OK;
VariantInit(&v);
VariantInit(&vValue);
CThreshold* pThreshold;
MY_OUTPUT(L"ENTER ***** CPolledMethodDataCollector::LoadInstanceFromMOF...", 4);
iSize = m_thresholdList.size();
for (i = 0; i < iSize ; i++)
{
MY_ASSERT(i<m_thresholdList.size());
pThreshold = m_thresholdList[i];
if (pThreshold->m_bValidLoad == FALSE)
return WBEM_E_INVALID_OBJECT;
}
if (m_szObjectPath)
{
delete [] m_szObjectPath;
m_szObjectPath = NULL;
}
if (m_szMethodName)
{
delete [] m_szMethodName;
m_szMethodName = NULL;
}
m_lNumInstancesCollected = 0;
iSize = m_parameterList.size();
for (i=0; i<iSize ;i++)
{
MY_ASSERT(i<m_parameterList.size());
pparameter = &m_parameterList[i];
if (pparameter->szName)
{
delete [] pparameter->szName;
}
if (pparameter->szValue)
{
delete [] pparameter->szValue;
}
}
m_parameterList.clear();
//
// Call the base class to load the common properties. Then do the specific ones.
//
hRetRes = CDataCollector::LoadInstanceFromMOF(pObj, pParentDG, pszParentObjPath, bModifyPass);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) return hRetRes;
hRetRes = GetStrProperty(pObj, L"ObjectPath", &m_szObjectPath);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
hRetRes = GetStrProperty(pObj, L"MethodName", &m_szMethodName);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
//
// Get the IN parameters from the Arguments property.
//
VariantInit(&v);
if ((hRetRes = pObj->Get(L"Arguments", 0L, &v, NULL, NULL)) == S_OK)
{
if (V_VT(&v)==VT_NULL)
{
// MY_ASSERT(FALSE);
}
else
{
MY_ASSERT(V_VT(&v)==(VT_UNKNOWN|VT_ARRAY));
SafeArrayGetLBound(v.parray, 1, &iLBound);
SafeArrayGetUBound(v.parray, 1, &iUBound);
if ((iUBound - iLBound + 1) == 0)
{
MY_ASSERT(FALSE);
}
else
{
for (i = iLBound; i <= iUBound; i++)
{
par.szName = NULL;
par.szValue = NULL;
VariantInit(&vValue);
vUnknown = NULL;
hRetRes = SafeArrayGetElement(v.parray, &i, &vUnknown);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
pCO = (IWbemClassObject *)vUnknown;
hRetRes = GetStrProperty(pCO, L"Name", &par.szName);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
hRetRes = GetUint32Property(pCO, L"Type", &lType);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
par.lType = lType;
hRetRes = GetStrProperty(pCO, L"Value", &par.szValue);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
m_parameterList.push_back(par);
VariantClear(&vValue);
vUnknown->Release();
}
}
}
}
else
{
MY_HRESASSERT(hRetRes);
return hRetRes;
}
VariantClear(&v);
MY_OUTPUT(L"EXIT ***** CPolledMethodDataCollector::LoadInstanceFromMOF...", 4);
return S_OK;
error:
MY_ASSERT(FALSE);
VariantClear(&v);
m_bValidLoad = FALSE;
Cleanup(FALSE);
if (m_szObjectPath)
{
delete [] m_szObjectPath;
m_szObjectPath = NULL;
}
if (m_szMethodName)
{
delete [] m_szMethodName;
m_szMethodName = NULL;
}
iSize = m_parameterList.size();
for (i=0; i<iSize ;i++)
{
MY_ASSERT(i<m_parameterList.size());
pparameter = &m_parameterList[i];
if (pparameter->szName)
{
delete [] pparameter->szName;
}
if (pparameter->szValue)
{
delete [] pparameter->szValue;
}
}
return hRetRes;
}
BOOL CPolledMethodDataCollector::CollectInstance(void)
{
BOOL bRetValue = TRUE;
int iSize;
int i;
PARSTRUCT *pparameter;
HRESULT hRetRes = S_OK;
VARIANT var;
SAFEARRAY* psa = NULL;
IWbemClassObject *pObj = NULL;
IWbemClassObject *pClass = NULL;
IWbemClassObject *pOutInst = NULL;
IWbemClassObject *pInClass = NULL;
IWbemClassObject *pInInst = NULL;
BSTR ClassPath = NULL;
BSTR MethodName = NULL;
INSTSTRUCT inst;
VariantInit(&var);
MY_OUTPUT(L"ENTER ***** CPolledMethodDataCollector::CollectInstance...", 1);
m_lNumInstancesCollected = 0;
if (m_pIWbemServices == NULL)
{
m_ulErrorCode = HMRES_BADWMI;
GetLatestAgentError(HMRES_BADWMI, m_szErrorDescription);
StoreStandardProperties();
return FALSE;
}
//
// We get an instance at a time, so we can set all to not needed first,
// then go through them, do StoreValues... and delete what is not needed.
//
//
// Mark each instance, so we can tell if we still need them.
//
#ifdef SAVE
iSize = m_pnList.size();
for (i = 0; i < iSize ; i++)
{
MY_ASSERT(i<m_pnList.size());
ppn = &m_pnList[i];
jSize = ppn->instList.size();
for (j = 0; j < jSize ; j++)
{
MY_ASSERT(j<ppn->instList.size());
pinst = &ppn->instList[j];
pinst->bNeeded = FALSE;
}
}
#endif
ClassPath = SysAllocString(m_szObjectPath);
MY_ASSERT(ClassPath); if (!ClassPath) {hRetRes = WBEM_E_OUT_OF_MEMORY; goto error;}
MethodName = SysAllocString(m_szMethodName);
MY_ASSERT(MethodName); if (!MethodName) {hRetRes = WBEM_E_OUT_OF_MEMORY; goto error;}
hRetRes = m_pIWbemServices->GetObject(ClassPath, 0, NULL, &pClass, NULL);
if (FAILED(hRetRes) || pClass == NULL)
{
m_lCurrState = HM_WARNING;
}
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK || pClass == NULL) goto error;
// Get the input-argument class object and create an instance.
hRetRes = pClass->GetMethod(MethodName, 0, &pInClass, NULL);
if (FAILED(hRetRes) || pClass == NULL)
{
m_lCurrState = HM_WARNING;
}
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK || pInClass == NULL) goto error;
hRetRes = pInClass->SpawnInstance(0, &pInInst);
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
//
// Set the IN parameters - they are actually properties on the instance we pass in.
// We will do error checking to make sure that there is one by that name, by seeing
// if the Put fails.
//
iSize = m_parameterList.size();
for (i=0; i<iSize ;i++)
{
MY_ASSERT(i<m_parameterList.size());
pparameter = &m_parameterList[i];
VariantInit(&var);
if (pparameter->lType == CIM_SINT8 ||
pparameter->lType == CIM_SINT16 ||
pparameter->lType == CIM_CHAR16)
{
V_VT(&var) = VT_I2;
V_I2(&var) = _wtol(pparameter->szValue);
}
else if (pparameter->lType == CIM_SINT32 ||
pparameter->lType == CIM_UINT16 ||
pparameter->lType == CIM_UINT32)
{
V_VT(&var) = VT_I4;
V_I4(&var) = _wtol(pparameter->szValue);
}
else if (pparameter->lType == CIM_REAL32)
{
V_VT(&var) = VT_R4;
V_R4(&var) = wcstod(pparameter->szValue, NULL);
}
else if (pparameter->lType == CIM_BOOLEAN)
{
V_VT(&var) = VT_BOOL;
V_BOOL(&var) = (BOOL) _wtol(pparameter->szValue);
}
else if (pparameter->lType == CIM_SINT64 ||
pparameter->lType == CIM_UINT64 ||
//XXX pparameter->lType == CIM_REF ||
pparameter->lType == CIM_STRING ||
pparameter->lType == CIM_DATETIME)
{
V_VT(&var) = VT_BSTR;
V_BSTR(&var) = SysAllocString(pparameter->szValue);
}
else if (pparameter->lType == CIM_REAL64)
{
V_VT(&var) = VT_R8;
V_R8(&var) = wcstod(pparameter->szValue, NULL);
}
else if (pparameter->lType == CIM_UINT8)
{
V_VT(&var) = VT_UI1;
V_UI1(&var) = (unsigned char) _wtoi(pparameter->szValue);
}
else
{
MY_ASSERT(FALSE);
}
hRetRes = pInInst->Put(pparameter->szName, 0, &var, 0);
MY_HRESASSERT(hRetRes);
VariantClear(&var);
if (psa != NULL)
{
SafeArrayDestroy(psa);
psa = NULL;
}
}
//
// Call the method.
//
hRetRes = m_pIWbemServices->ExecMethod(ClassPath, MethodName, WBEM_FLAG_RETURN_IMMEDIATELY, m_pContext, pInInst, &pOutInst, &m_pCallResult);
if (hRetRes != S_OK)
{
MY_HRESASSERT(hRetRes);
MY_OUTPUT2(L"PMDE - ExecMethod Error: 0x%08x",hRetRes,4);
MY_OUTPUT2(L"m_szGUID was=%s",m_szGUID,4);
m_ulErrorCode = hRetRes;
GetLatestWMIError(HMRES_OBJECTNOTFOUND, hRetRes, m_szErrorDescription);
StoreStandardProperties();
bRetValue = FALSE;
}
else
{
m_bKeepCollectingSemiSync = TRUE;
bRetValue = CollectInstanceSemiSync();
}
//
// Free up resources.
//
SysFreeString(ClassPath);
ClassPath = NULL;
SysFreeString(MethodName);
MethodName = NULL;
pClass->Release();
pClass = NULL;
pInInst->Release();
pInInst = NULL;
pInClass->Release();
pInClass = NULL;
MY_OUTPUT(L"EXIT ***** CPolledMethodDataCollector::CollectInstance...", 1);
return bRetValue;
error:
MY_ASSERT(FALSE);
if (ClassPath)
SysFreeString(ClassPath);
if (MethodName)
SysFreeString(MethodName);
if (pClass)
pClass->Release();
if (pInInst)
pInInst->Release();
if (pInClass)
pInClass->Release();
if (psa != NULL)
SafeArrayDestroy(psa);
m_bValidLoad = FALSE;
Cleanup(FALSE);
return hRetRes;
}
BOOL CPolledMethodDataCollector::CollectInstanceSemiSync(void)
{
HRESULT hRetRes = S_OK;
IWbemClassObject *pObj = NULL;
PNSTRUCT *ppn;
INSTSTRUCT inst;
CThreshold *pThreshold;
long lStatus;
ULONG uReturned = 0;
int i, iSize;
InstIDSTRUCT InstID;
MY_OUTPUT(L"ENTER ***** CPolledMethodDataCollector::CollectInstanceSemiSync...", 1);
MY_ASSERT(m_pCallResult);
lStatus = 0;
//
// Keep trying until we get WBEM_S_NO_ERROR. Then we know the GetObject call has completed.
// hRes will contain the result of the origional GetObject call if needed.
//
hRetRes = m_pCallResult->GetCallStatus(0, &lStatus);
if (hRetRes == WBEM_S_TIMEDOUT)
{
return FALSE;
}
else if (hRetRes == WBEM_S_NO_ERROR)
{
// Means that we have an instance
}
else
{
MY_HRESASSERT(hRetRes);
MY_OUTPUT2(L"PMDE - GetCallStatus Error: 0x%08x",hRetRes,4);
MY_OUTPUT2(L"m_szGUID was=%s",m_szGUID,4);
MY_OUTPUT2(L"ClassPath was=%s",m_szObjectPath,4);
MY_OUTPUT2(L"MethodName was=%s",m_szMethodName,4);
m_ulErrorCode = 0;
EnumDone();
return FALSE;
}
//
// This may mean that the call completed, and the object was not found (e.g. bad path).
//
if (lStatus != 0)
{
m_lCurrState = HM_WARNING;
m_ulErrorCode = 0;
EnumDone();
return FALSE;
}
//
// Get the Object finaly.
//
hRetRes = m_pCallResult->GetResultObject(0, &pObj);
if (pObj == NULL)
{
//
// NULL in this case can actually happen. An example is where the
// threshold is to see if the SQL Server service is running. If it
// is not even on the machine, then we would get an error looking
// for its instance.
//
m_lCurrState = HM_WARNING;
EnumDone();
}
else
{
EnumDone();
//
// Figure out the key property name to identify instances with.
//
iSize = m_instIDList.size();
if (iSize == 0)
{
// There is no key property returned!!!
InstID.szInstanceIDPropertyName = new TCHAR[7];
MY_ASSERT(InstID.szInstanceIDPropertyName); if (!InstID.szInstanceIDPropertyName) {hRetRes = WBEM_E_OUT_OF_MEMORY; goto error;}
wcscpy(InstID.szInstanceIDPropertyName , L"Method");
m_instIDList.push_back(InstID);
// Add an instance to each property name
iSize = m_pnList.size();
for (i=0; i < iSize ; i++)
{
MY_ASSERT(i<m_pnList.size());
ppn = &m_pnList[i];
inst.szInstanceID = new TCHAR[2];
MY_ASSERT(inst.szInstanceID); if (!inst.szInstanceID) {hRetRes = WBEM_E_OUT_OF_MEMORY; goto error;}
wcscpy(inst.szInstanceID, L"");
inst.szCurrValue = NULL;
ResetInst(&inst, ppn->type);
inst.bNull = FALSE;
inst.bNeeded = TRUE;
ppn->instList.push_back(inst);
}
//Also add instance for all thresholds under this DataCollector
iSize = m_thresholdList.size();
for (i=0; i < iSize ; i++)
{
MY_ASSERT(i<m_thresholdList.size());
pThreshold = m_thresholdList[i];
hRetRes = pThreshold->AddInstance(L"");
MY_HRESASSERT(hRetRes); if (hRetRes!=S_OK) goto error;
}
}
MY_ASSERT(m_instIDList.size());
//
// Check the list of actual instances that the Data Collector is collecting.
// We keep around the latest one(s) for the DataCollector.
//
CheckActualInstanceExistance(pObj, L"");
m_lNumInstancesCollected = 1;
StoreValues(pObj, L"");
pObj->Release();
pObj = NULL;
//
// Means that we are done.
// Won't ever get here the first time
// Add in a fake instance for the number of instances returned.
//
m_lCurrState = HM_GOOD;
m_ulErrorCode = 0;
StoreStandardProperties();
}
MY_OUTPUT(L"EXIT ***** CPolledMethodDataCollector::CollectInstanceSemiSync...", 1);
return TRUE;
error:
MY_ASSERT(FALSE);
if (pObj)
pObj->Release();
m_bValidLoad = FALSE;
Cleanup(FALSE);
return FALSE;
}
BOOL CPolledMethodDataCollector::CleanupSemiSync(void)
{
if (m_pCallResult)
{
m_pCallResult->Release();
m_pCallResult = NULL;
}
m_bKeepCollectingSemiSync = FALSE;
m_lCollectionTimeOutCount = 0;
return TRUE;
}
BOOL CPolledMethodDataCollector::EnumDone(void)
{
CleanupSemiSync();
return TRUE;
}