there is a single difference between command line
parameters of plasmapkg2 and kpackagetool5: plasmapkg2
had some hardcoded names like "theme", "plasmoid" etc.
kpackagetool5 requires the servicetype name to be
passed instead. in order to stay compatible convert
those parameter with the proper servicetype name.
it's parsing parameters by hand in order to just
pass anything else without further parsing
BUG:374463
REVIEW:129753
Change-Id: I6adece9b3dd351331d747505c455e0f79cd0ecf7
They are supposed to be lists. This fixes dropping folders on desktops to create a FolderView.
Dropping trash:/ also offers to create a trash applet again.
BUG: 374418
Differential Revision: https://phabricator.kde.org/D3902
This makes it consistent with the Breeze widget style.
The other themes (Air and Oxygen) didn't even have a scroll bar background.
Differential Revision: https://phabricator.kde.org/D3828
--the dialogs shown from dock type windows when
the dock uses masking are placed far from the
the element that triggered them. This patch
fixes this bug and provide also an auto test.
They're supposed to do the same, completely different codebases. Also some
things had to be ported.
I'd recommend everything to be ported to use kpackagetool (knsrc files!)
but still it's better to at least make sure we stick to one set of features.
REVIEW: 129704
Summary:
As Plasma::Package is deprecated API using Plasma::Package should also
be deprecated.
Reviewers: #plasma, #frameworks
Subscribers: plasma-devel
Tags: #plasma
Differential Revision: https://phabricator.kde.org/D3812
Summary:
Appmenu quite neatly has a config option for which should be the
preferred representation, which is needed as both things are quite
viable in a panel and can't be done automatically.
AppletQuickItem needs to update which representation to use when this is
set at runtime. We already check on every single geometry change, so
one extra check won't have a huge impact.
Test Plan:
Appmenu changes dynamically
All other applets (both compact and normal) still seem fine
Reviewers: #plasma, mart
Reviewed By: mart
Subscribers: plasma-devel
Tags: #plasma
Differential Revision: https://phabricator.kde.org/D3794
Summary: Ref T4947
Test Plan: works on desktop at least, haven't tested on phone yet
Reviewers: #plasma, mart
Reviewed By: mart
Subscribers: plasma-devel
Tags: #plasma
Maniphest Tasks: T4947
Differential Revision: https://phabricator.kde.org/D3789
if a panel doesn't ahve applets, it can't have a "currently
loading" as the status of its applets.
this fixes panels sometimes not showing up when reconnecting screens
CCBUG:373836
Summary:
The fallback for toolTipMainText is showing the applet title.
When the applet title changes, it may result in a change of
toolTipMainText.
Reviewers: #plasma
Subscribers: plasma-devel
Tags: #plasma
Differential Revision: https://phabricator.kde.org/D3760
This introduces a new lineedit_reveal_password restriction (similar to lineedit_text_completion)
that disables the reveal password button on Plasma text fields, like the lock screen and WiFi password inputs.
Differential Revision: https://phabricator.kde.org/D3654
Now that we can have C++ applet we can make use of setLaunchErrorMessage
to communicate a fatal error in the applet initialization.
Differential Revision: https://phabricator.kde.org/D3725
Test Plan: less warnings when compiling plasma-workspace
Reviewers: #plasma, mart
Reviewed By: mart
Subscribers: plasma-devel
Tags: #plasma
Differential Revision: https://phabricator.kde.org/D3679
settingsFileChanged is called if the plugin metadata file changes, and
reloads the theme if the version changes.
However, if the metadata file now doesn't exist we need to check before
calling .version() otherwise it will assert.
If it doesn't exist, we want to reload the theme so that it will load
the correct thing.
BUG: 372651
REVIEW: 129436
when the tabbar is vertical, on rtl layout the tabs order should
stay as is, as is rtl, not bottom-to-top
Change-Id: Ia5f1722d5e327207cf584a997dc8073c595c905b
REVIEW:129521
When closing the launcher using Meta key, it pulls focus away and when
clicking the button to expand the applet, it won't get focus again.
BUG: 372476
REVIEW: 129404
Summary: Depends on D3299.
Test Plan: plasma still starts with all plasmoids
Reviewers: #plasma, mart
Reviewed By: mart
Subscribers: plasma-devel
Tags: #plasma
Differential Revision: https://phabricator.kde.org/D3311
As https://bugs.kde.org/show_bug.cgi?id=369622#c5 mentioned,
if icon has both 22px and 32px sizes, the 22px one should
have prefix of 22-22- in object ID while the 32px one shouldn't.
Checked all existing icons and to correct wrong IDs.
patch by Yunhe Guo <guoyunhebrave@gmail.com>
CCMAIL:guoyunhebrave@gmail.com
BUG:369622
Change-Id: I9d8728cfa9ce47aaaaa3b0e5042ed616f142c19a
REVIEW:129329