Summary:
Allow compaction_job_test, db_io_failure_test, dbformat_test, deletefile_test, and fault_injection_test to use a custom Env object. Also move ```RegisterCustomObjects``` declaration to a header file to simplify things.
Pull Request resolved: https://github.com/facebook/rocksdb/pull/9087
Test Plan: Run manually using "buck test rocksdb/src:compaction_job_test_fbcode" etc.
Reviewed By: riversand963
Differential Revision: D32007222
Pulled By: anand1976
fbshipit-source-id: 99af58559e25bf61563dfa95dc46e31fa7375792
Summary:
The PerThreadDBPath has already specified a slash. It does not need to be specified when initializing the test path.
Pull Request resolved: https://github.com/facebook/rocksdb/pull/8555
Reviewed By: ajkr
Differential Revision: D29758399
Pulled By: jay-zhuang
fbshipit-source-id: 6d2b878523e3e8580536e2829cb25489844d9011
Summary:
When WriteBufferManager is shared across DBs and column families
to maintain memory usage under a limit, OOMs have been observed when flush cannot
finish but writes continuously insert to memtables.
In order to avoid OOMs, when memory usage goes beyond buffer_limit_ and DBs tries to write,
this change will stall incoming writers until flush is completed and memory_usage
drops.
Design: Stall condition: When total memory usage exceeds WriteBufferManager::buffer_size_
(memory_usage() >= buffer_size_) WriterBufferManager::ShouldStall() returns true.
DBImpl first block incoming/future writers by calling write_thread_.BeginWriteStall()
(which adds dummy stall object to the writer's queue).
Then DB is blocked on a state State::Blocked (current write doesn't go
through). WBStallInterface object maintained by every DB instance is added to the queue of
WriteBufferManager.
If multiple DBs tries to write during this stall, they will also be
blocked when check WriteBufferManager::ShouldStall() returns true.
End Stall condition: When flush is finished and memory usage goes down, stall will end only if memory
waiting to be flushed is less than buffer_size/2. This lower limit will give time for flush
to complete and avoid continous stalling if memory usage remains close to buffer_size.
WriterBufferManager::EndWriteStall() is called,
which removes all instances from its queue and signal them to continue.
Their state is changed to State::Running and they are unblocked. DBImpl
then signal all incoming writers of that DB to continue by calling
write_thread_.EndWriteStall() (which removes dummy stall object from the
queue).
DB instance creates WBMStallInterface which is an interface to block and
signal DBs during stall.
When DB needs to be blocked or signalled by WriteBufferManager,
state_for_wbm_ state is changed accordingly (RUNNING or BLOCKED).
Pull Request resolved: https://github.com/facebook/rocksdb/pull/7898
Test Plan: Added a new test db/db_write_buffer_manager_test.cc
Reviewed By: anand1976
Differential Revision: D26093227
Pulled By: akankshamahajan15
fbshipit-source-id: 2bbd982a3fb7033f6de6153aa92a221249861aae