Jay Edgar b345b36620 Add a minimum value for the refill bytes per period value
Summary: If the user specified a small enough value for the rate limiter's bytes per second, the calculation for the number of refill bytes per period could become zero which would effectively cause the server to hang forever.

Test Plan: Existing tests

Reviewers: sdong, yhchiang, igor

Reviewed By: igor

Subscribers: leveldb, andrewkr, dhruba

Differential Revision: https://reviews.facebook.net/D56631